Electrical Faults In Full Air Conditioning Systems Didactic Equipment Vocational Education Equipment Refrigeration Training Equipment

Item No.: ET 174
Electrical Faults In Full Air Conditioning Systems Didactic Equipment Vocational Education Equipment Refrigeration Training Equipment
Description
ET 174 Electrical Faults In Full Air Conditioning Systems Didactic Equipment Vocational Education Equipment Refrigeration Training Equipment

Simulation of the electrical circuit of a complex conditioning system with humidifying and heat pump function
Features
- simulation of the electrical circuit of a complex conditioning system with humidifying and heat pump function
- investigation of key electrical components from air conditioning technology
- simulation of 30 faults
Learning objectives/experiments
- electrical design and operation of full conditioning systems
- reading and understanding electrical circuit diagrams
- design and operation of electrical components in an air conditioning system
-- start-up capacitor
-- start-up relay
-- operating capacitor
-- overheat protection
-- Heinemann circuit breaker
-- solenoid valve
-- defrost timer
-- float switch
-- thermostat
-- hygrostat
-- frost protection monitor
- fault finding in electrical components
-- in idle state
-- under mains voltage
Specification
[1] experimental unit from the  practical series for the training of mechatronics engineers for refrigeration
[2] simulation of the electrical circuit of a complex conditioning system with humidifier and heat pump function for heating, cooling and humidifying
[3] real control circuits with electrical components, simulated load circuits
[4] electrical simulation of compressor, 2 fans (room air, outer air), four-way reversing valve, auxiliary heating
[5] humidifier with hygrostat, solenoid valve and float switch (pump simulated)
[6] hot gas defrosting by switching the four-way reversing valve
[7] operating states of the simulated components indicated via lamps in the circuit diagram
[8] circuit diagram depicted on the front panel
[9] identification of 30 faults: multimeter measures voltages or resistances at the lab jacks


Technical data
Thermostat to switch between heating/cooling
- measuring range: 1...60°C
Electrical compressor components
- start-up relay
- start-up capacitor
- operating capacitor
- overheat protection
- 2 pressure switches
Electrical components of room air fan
- start-up capacitor
- Heinemann circuit breaker
Humidifier components
- hygrostat: measuring range 30...100% r.h.
- float switch
- solenoid valve
- Heinemann circuit breaker
Defrosting components
- frost protection monitor: -10...12°C
- timer: switching time 10...60min
Circuit breaker for auxiliary heating
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase
UL/CSA optional
LxWxH: 1050x400x860mm
Weight: approx. 48kg